Thank you for choosing Commercial Air Conditioners ,please read this owner’s manual carefully before operation and retain it for future reference.
Wired Controller
XK41 & XK47
Commercial Air Conditioners
Owner's Manual


User Notice
Please carefully read this manual before installation and use of this product

Ensure unified power supply for each indoor unit.

Never install wired controller in wet place or under sunlight directly.

Shielded twisted pair line must be adopted as signal line or wiring (communication) of wired controller once the unit is installed in the place where there is electromagnetic interference.

Make sure communication line is connected into correct port to avoid communication malfunction.

Never knock, throw or frequently disassemble the wired controller.

Never operate the wired controller with wet hand.


Contents
1 Displaying Part ................................................................................................1 1.1 LCD Display of Wired Controller ................................................................ 1 1.2 Instruction to LCD Display .......................................................................... 2 2 Buttons ............................................................................................................3 2.1 Layout of Buttons .......................................................................................3 2.2 Functions of Buttons ...................................................................................3 3 Operation Instructions .....................................................................................4 3.1 On/Off ......................................................................................................... 4 3.2 Mode Setting .............................................................................................. 4 3.3 Temperature Setting ...................................................................................4 3.4 Fan Setting ................................................................................................. 5 3.5 Timer Setting .............................................................................................. 5 3.6 Swing Setting ............................................................................................. 7 3.7 Sleep Setting .............................................................................................. 8 3.8 Turbo Setting .............................................................................................. 9 3.9 E-heater Setting .......................................................................................10 3.10 Blow Setting ........................................................................................... 11 3.11 Other Functions ......................................................................................12 4 Installation and Dismantlement .....................................................................12 4.1 Connection of the Signal Line of the Wired Controller ............................. 12 4.2 Installation of the Wired Controller ........................................................... 12 4.3 Dismantlement of the Wired Controller .................................................... 14 5 Errors Display ................................................................................................14


Wired Controller XK41 & XK47 1
1 Displaying Part
Fig1.1.1 Outline of wired controller
1.1 LCD Display of Wired Controller
Fig.1.1.2 LCD display


Wired Controller XK41 & XK47 2
1.2 Instruction to LCD Display
Table 1.1
No.
Symbols
Description
1
Swing function
2
Air exchange function (this function is yet unavailable for this unit).
3
Sleep function (Only sleep 1).
4
Each kind of running mode of indoor unit (auto mode)
5
Cooling mode
6
Dry mode
7
Fan mode
8
Heating mode
9
Defrosting function for the outdoor unit.
10
Gate-control function (this function is yet unavailable for this unit).
11
Lock function.
12
SHIELD
Shield functions (Button operation, temperature setting, On/Off operation,
Mode setting are disabled by the remote monitoring system.)
13
Turbo
Turbo function state
14
MEMORY
Memory function (The indoor unit resumes the original setting state after power failure and then power recovery).
15
It blinks under on state of the unit without operation of any button.
16
SAVE
Energy-saving function (this function is yet unavailable for this unit).
17
Ambient/setting temperature value
18
E-HEATER
Electric auxiliary heating function.
19
BLOW
Blow function.
20
Timing value.
21
QUIET
Quiet function (two types: quiet and auto quiet)
(this function is yet unavailable for this unit).


Wired Controller XK41 & XK47 3
2 Buttons
2.1 Layout of Buttons
2.2 Functions of Buttons
Table 2.1
No.
Name
Function
1
Enter/Cancel
Function selection and cancellation.
2

① .
Running temperature setting of the indoor unit, range:16 30
o
C.
② .
Timer setting, range:0.5-24 hr.
6

3
Fan
Setting of the high/middle/low/auto fan speed.
4
Mode
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5
Function
Switchover among the functions of Turbo/Save/E-heater/Blow etc..
7
Timer
Timer setting.
8
On/Off
Turn on/off the indoor unit
4+2
▲+Mode
Press them for 5s under off state of the unit to enter/cancel the Memory function(If memory is set, indoor unit after power failure and then power recovery will resume the original setting state. If not, the indoor unit is defaulted to be off after power recovery. Memory off is default before delivery.).
3+6
Fan+▼
By pressing them at the same time under off state of the unit, will be displayed on the wired controller for the cooling only unit, while will be displayed on the wired controller for the cooling and heating unit.
2+6
▲+▼
Upon startup of the unit without malfunction or under off state of the unit,press them at the same time for 5s to enter the lock state, in which case,any other buttons won’t respond the press. Repress them for 5s to quit this state.


Wired Controller XK41 & XK47 4
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.3.1.1 indicates the “Off” state of the unit after power on. The state shown in Fig.3.1.2 indicates the “On” state of the unit after power on.
Fig.3.1.1 “Off” State Fig.3.1.2 “On” State
3.2 Mode Setting
Under ON state of the unit, press the Mode to switch the operation modes as the following sequence:Auto–Cooling–Dry–Fan–Heating.
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If pressing either of them continuously, the temperature will be increased or decreased by 1°C every 0.5s,as shown in
Fig.3.3.1.
In the Cooling, Dry, Fan or Heating mode, the temperature setting range is 16°C
30°C.
In the Auto mode, the setting temperature is unadjustable.
Fig.3.3.1 Fig.3.4.1


Wired Controller XK41 & XK47 5
3.4 Fan Setting
Under the “On” state of the unit, press Fan and then fan speed of the indoor unit will change circularly as shown in Fig.3.4.1.
Low
Middle
High
3.5 Timer Setting
Under on-state of the unit, Press Timer button to set timer off of the unit. Under off-state of the unit, press Timer button to set timer on of the unit in the same way.
• Timer on setting:
Under off-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
Hour,with ON blinking. In this case, press▲ or ▼ button to adjust timer on and then press Timer to confirm.
• Timer off setting:
Under on-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
Hour,with OFF blinking. In this case, press▲ or ▼ button to adjust timer on and then press Timer to confirm.
• Cancel timer:
After setting of timer, if Timer button is pressed, LCD won’t display xx. Hour so that timer setting is canceled.
Timer off setting under the “On” state of the unit is shown as Fig.3.5.1.
Fig.3.5.1 Timer off Setting under the “On”
State of the Unit


Wired Controller XK41 & XK47 6
Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.
Fig.3.5.2 Timer on Setting under the “Off”
State of the Unit
Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by
0.5hr. If either of them is pressed continuously, the set time will increase/ decrease by 0.5hr every
0.5s.


Wired Controller XK41 & XK47 7
3.6 Swing Setting
Swing On: Press Function under on state of the unit to activate the swing function. In this case, will blink. After that, press Enter/Cancel to make a confirmation.
Swing Off: When the Swing function is on, press Function to enter the Swing setting interface,with blinking. After that, press Enter/Cancel to cancel this function. Swing setting is shown as Fig.3.6.1.
Fig.3.6.1 Swing Setting
Notes:
① .
Sleep, Turbo or Blow setting is the same as the Swing setting.
② .
After the setting has been done, it has to press the key “Enter/Cancel” to back to the setting status or quit automatically five seconds later.


Wired Controller XK41 & XK47 8
3.7 Sleep Setting
Sleep on: Press Function under the On state of the unit till the unit enters the Sleep setting state. After that, press Enter/Cancel to confirm this setting.
Sleep off: When the Sleep function is activated, press Function to enter the Sleep setting status. After that, press Enter/Cancel to cancel this function.
In the Cooling or Dry mode, the temperature will increase by 1°C after the unit runs under
Sleep1 for 1hr and 1°C after another 1hr.After that, the unit will run at this temperature.
In the Heating mode, the temperature will decrease by 1°C after the unit runs under Sleep 1 for
1hr and 1°C after another 1hr. After that, the unit will run at this temperature.
Sleep setting is shown as Fig.3.7.1.
Fig.3.7.1. Sleep Setting


Wired Controller XK41 & XK47 9
3.8 Turbo Setting
Turbo function: The unit at the high fan speed can realize quick cooling or heating so that the room temperature can quickly approach the setting value.
In the Cooling or Heating mode, press Function till the unit enters the Turbo setting status and then press Enter/Cancel to confirm the setting.
When the Turbo function is activated, press Function to enter the Turbo setting status and then press Enter/Cancel to cancel this function.
Turbo function setting is as shown in Fig.3.8.1.
Fig.3.8.1 Turbo Setting


Wired Controller XK41 & XK47 10 3.9 E-heater Setting
E-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to be turned on for improvement of efficiency.
Once the wired controller or the remote controller enters the Heating mode, this function will be turned on automatically.
Press Function in the Heating mode to enter the E-heater setting interface and then press
Enter/Cancel to cancel this function.
Press Function to enter the E-heater setting status, if the E-heater function is not activated, and then press Enter/Cancel to activate it.
The setting of this function is shown as Fig.3.9.1 below:
Fig.3.9.1 E-heater Setting


Wired Controller XK41 & XK47 11 3.10 Blow Setting
Blow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid mildew.
In the Cooling or Dry mode, press Function till the unit enters the Blow setting status and then press Enter/Cancel to active this function.
When the Blow function is activated, press Function to the Blow setting status and then press
Enter/Cancel to cancel this function.
Blow function setting is as shown in Fig.3.10.1
Fig.3.10.1 Blow Setting
Notes:
① .
When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote controller, the indoor fan will run at the low fan speed for 2 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly.
② .
Blow function is unavailable in the Fan or Heating mode.


Wired Controller XK41 & XK47 12 3.11 Other Functions
a. Lock
Upon startup of the unit without malfunction or under the “Off” state of the unit, press ▲ and ▼ at the same time for 5s till the wired controller enters the Lock function. In this case, LCD displays .
After that, repress these two buttons at the same time for 5s to quit this function.
Under the Lock state, any other button press won’t get any response.