Parameter
Default
Value
Profile-Specific Allowed Values
Description
address
1
String with 1 character
Address for WMT700
autoInt
1 0.25 ... Resolution Automatic message interval in seconds. Do not select a message interval that is shorter than the time it takes to send a data message
WMT700 User Guide
M211095EN-H
142


Parameter
Default
Value
Profile-Specific Allowed Values
Description
autoPort
1 1 = COM port = COM port
Serial port to which WMT700
sends automatic data messages autoSend
0 0 = Automatic messages disabled = NMEA automatic data message
Automatic data message number.
Selects the data message format for automatic messages com1_protocol
0 1)
4 = WS425 AB NMEA Standard
Profile for serial port COM1
com2_protocol
0 4 = WS425 AB NMEA Standard
Profile for serial port COM2
com2_interf
N/A
2)
0 = RS 1 = RS 3 = RS-232
Interface for serial port COM2
wndAvg
1 0.25 Resolution Averaging time for wind measurement in seconds wndOrientation 0 0 = Array facing up = Array facing down
Orientation of the array of
WMT700
wndUnit
0 2)
0 = Meters per second = Miles per hour = Kilometers per hour = Knots
Wind speed unit wndVector
1 0 = Scalar averaging
Wind averaging method
1)
The parameter has no protocol-specific default value. It is determined separately in the configuration code.
2) Wind speed unit and COM digital communication interface are defined in the order form. Default setting maybe any of the
allowed options, and it can be verified from the unit’s configuration code.
5.22.1 WS425 AB NMEA Standard Data Message
The standard variable length, comma-separated, MWV wind message is defined by NMEA
0183 V as follows:
$WIMWV,,,,,*
$WIMWV
Fixed text

Wind angle 0 to 359 degrees

Reference: R = Relative

Wind speed

Wind speed unit:
• K = Kilometers per hour
• M = Meters per second
• N = Knots
Chapter 5 – Operation
143



Status:
• A = Data valid
• V = Invalid data
*
Fixed text

Checksum (bit XOR, excluding $ and *)

Carriage return code, ASCII 0DH

Line feed code, ASCII 0AH
When the NMEA Standard profile is selected, the
autoInt parameter must have anon- zero value since no polling command is defined for this profile.
Missing Readings
If data is missing due to a measurement problem, the NMEA messages show V in the status field. Wind speed and wind direction fields are left empty WS425 NMEA Extended Profile
(v. When the WS425 AB NMEA Extended profile is selected, you can set WMT700 to send messages based on the configured automatic message interval or poll data using the
$WIP
command.
Table 51 WS425 NMEA Extended Profile Parameter Descriptions


Document code
Testsetup according to
More information
Optiontemperature range
Optionheating
Optionhardware interface
Optionunit used
Optionoutput configuration
Selectionoutput configuration
Optionadapter type
Optionaccessories
Order codedescription
Aout1 selected option
Output signal
Swnddiroffset,(angle)
Parameterdefinition
Power supplywire colors
Used heating option
Heating option
Wire type/cable length
Descriptionspare part item
Wmt700connector pin
Open commandto activate the command, press enter
Commanddescription
Wind_getfetches wind calibration information.more information
S command. power must be on for at least 5 seconds after the s
Startcommand.more information
Itemdescription
Bitdescription
G command to fetch the current wmt700 parameters. disable error messages with the command s messages,0
Errors. if all values are valid, wmt700 sends the following response:0,0,0,0you can also use the g
Data message number
Ws425 and sdi messages
Parametername
Parameterdefault
Start command.to stop measurement, use the stop
Wb,wfirmware
Wf output:wff6785672109876.5432.1k99xx5.21.2 ws425 f/g asos data messagewmt700 responds to the wa
Bytedescription
Parameterdefault value
Id character
Wx command with a character fixed-length data message.character
Start command. to stop measurement, use thestop
Problemprobable cause
Error/eventcode
Parameter name
Propertydescription/value
Analog outputs for wind direction
Itemorder code
Configuration mode / measurement
Settingparameter
Start command. you can stop the measurement with the stop
Example of the command and response:
Baud........................................................................ 105clearerr
S............................................................................... 103sleep
Gget message. get parameter.........................................................104h
Jjunction box...............................................................28l



Share with your friends:
1   ...   75   76   77   78   79   80   81   82   ...   125


The database is protected by copyright ©userg.info 2017
send message

    Main page

bosch
camera
chevrolet
epson
fiat
Honda
iphone
mitsubishi
nissan
Panasonic
Sony
volvo
xiaomi
Xperia
yamaha