Setting
Parameter
WMT700
WS425
ASCII
WS425
NMEA
Ext
WS425
SDI-12
WS425
F/G
ASOS
ROSA
MES12
Service port
Protocol com1_protocol
WMT700
WMT700
WMT700
WMT700
WMT700
WMT700
Baud rate com1_baud
9600 9600 9600 9600 9600 Data bits com1_data
8 8
8 8
8 Parity com1_parity
0 (None (None (None (None (None (None)
Stop bits com1_stop
1 1
1 1
1 1
Response
Delay com1_delay
20 ms ms ms ms ms ms
Data Port
Protocol com2_protocol
WMT700
WS425
ASCII
WS452
NMEA Ext
SDI-12
WS425
F/G ASOS
ROSA
MES12
Baud rate com2_baud
9600 2400 9600 1200 2400 Data bits com2_data
8 8
8 7
8 Parity com2_parity
0 (None (None (None (Even (None (None)
Stop bits com2_stop
1 1
1 1
1 1
Response
Delay com2_delay
20 ms ms ms
N/A
20 ms ms
Other Parameters
Address address
A
A
A
0 Automatic message number autoSend
Disabled
(0)
Disabled
15
Disabled
Disabled
Disabled
Appendix C – Default Settings for Different Communication Profiles
185


Setting
Parameter
WMT700
WS425
ASCII
WS425
NMEA
Ext
WS425
SDI-12
WS425
F/G
ASOS
ROSA
MES12
Automatic message port autoPort
COM1
COM1
COM2
COM1
COM1
COM1
Automatic data message interval autoInt
1 s s s s s s
Wind averaging time wndAvg
1 s s s s s s
Gust averaging time wndGustTime
3 s s s s s s
Installa- tion orientation of
WMT700
wndOrientation
Array facing up
Array facing up
Array facing up
Array facing up
Array facing up
Array facing up
Wind measurement averaging method wndVector
Scalar averaging
Scalar averaging
Scalar averaging
Scalar averaging
Scalar averaging
Scalar averaging
The parameters in the following table do not have a protocol-specific default value. They are defined in the configuration code.
Table 72 Parameters with No Protocol-specific Default Value
Setting
Parameter
WMT700
WS425
ASCII
WS425
NMEA
Ext
WS425
SDI-12
WS425
F/G
ASOS
ROSA
MES12
Interface type com2Interf
N/A
N/A
N/A
N/A
N/A
N/A
Wind speed unit wndUnit
N/A
N/A
N/A
N/A
N/A
N/A
WMT700 User Guide
M211095EN-H
186

Appendix D. Configuration
Parameter Descriptions
Table 73 Configuration Parameter Descriptions
Parameter Name
Default
Value
Allowed Values
Units
Description
address
A
String with a maximum of 40
characters.
Address for WMT700. Note that the SDI, ASCII, NMEA
Extended, ASOS, and MES12
profiles use the first character only. SDI only uses digits 1 …
9.
aout1erraout2err
1000 0 VA, Hz, Value for AOUT1 and AOUT2
analog output if wind measurement fails.
aout1_gaout2_g
1 0 ... Gain for AOUT1 (wind speed)
and AOUT2 (wind direction)
aout1_oaout2_o
0
-10000 Offset for AOUT1 and AOUT2
aout1maxvaout2maxv
32000 0 VA, Hz, Analog output maximum value for AOUT1 and AOUT2. The output is fixed to this value.
The unit depends on analog output mode.
aout1minvaout2minv
0 0 VA, Hz, Analog output minimum value for AOUT1 and AOUT2. The output is fixed to this value.
The unit depends on the analog output mode.
aout1mode
3 0 = Current = Voltage = Frequency = Disabled
Analog output mode for
AOUT1.
aout2mode
7 4 = Current = Voltage =
Potentiometer
7 = Disabled
Analog output mode for
AOUT2.
autoInt
1 0.25 ... Resolution 0.25
s
Automatic message interval in seconds. This parameter affects both serial communication and analog output. Do not select a message interval that is shorter than the time it takes to send a data message.
Appendix D – Configuration Parameter Descriptions
187




Document code
Testsetup according to
More information
Optiontemperature range
Optionheating
Optionhardware interface
Optionunit used
Optionoutput configuration
Selectionoutput configuration
Optionadapter type
Optionaccessories
Order codedescription
Aout1 selected option
Output signal
Swnddiroffset,(angle)
Parameterdefinition
Power supplywire colors
Used heating option
Heating option
Wire type/cable length
Descriptionspare part item
Wmt700connector pin
Open commandto activate the command, press enter
Commanddescription
Wind_getfetches wind calibration information.more information
S command. power must be on for at least 5 seconds after the s
Startcommand.more information
Itemdescription
Bitdescription
G command to fetch the current wmt700 parameters. disable error messages with the command s messages,0
Errors. if all values are valid, wmt700 sends the following response:0,0,0,0you can also use the g
Data message number
Ws425 and sdi messages
Parametername
Parameterdefault
Start command.to stop measurement, use the stop
Wb,wfirmware
Wf output:wff6785672109876.5432.1k99xx5.21.2 ws425 f/g asos data messagewmt700 responds to the wa
Bytedescription
Parameterdefault value
Id character
Wx command with a character fixed-length data message.character
Start command. to stop measurement, use thestop
Problemprobable cause
Error/eventcode
Parameter name
Propertydescription/value
Analog outputs for wind direction
Itemorder code
Configuration mode / measurement
Start command. you can stop the measurement with the stop
Example of the command and response:
Baud........................................................................ 105clearerr
S............................................................................... 103sleep
Gget message. get parameter.........................................................104h
Jjunction box...............................................................28l



Share with your friends:
1   ...   105   106   107   108   109   110   111   112   ...   125


The database is protected by copyright ©userg.info 2017
send message

    Main page

bosch
camera
chevrolet
epson
fiat
Harley Davidson
Honda
iphone
mitsubishi
nissan
Panasonic
Sony
volvo
xiaomi
Xperia
yamaha