QC-5002
Through-the-Wall Coin Change Machine
Instruction Manual
Anztec, P.O. Box 3288, Christchurch, New Zealand
Phone +64 3 338 3139 www.anztec.com email: sales@anztec.com
Serial #
Key #
Software Ver.


QC-5002 Page
2


QC-5002 Page
3
Contents
Installation ................................................................................... 4
Overview ..............................................................................................................................................4
Start Up.................................................................................................................................................4
Reset Meters and Events to zero...........................................................................................................5
Fill Hoppers..........................................................................................................................................5
Daily Management....................................................................... 6
Overview ..............................................................................................................................................6
Enter Attendant Mode ..........................................................................................................................6
Access Event Log .................................................................................................................................7
Event List .............................................................................................................................................8
Access Accountancy Menu ..................................................................................................................9
Accountancy Meter List ..................................................................................................................... 10
Clear Short Term Meters .................................................................................................................... 11
GBA Note Acceptor Maintenance ............................................ 12
Equipment Required........................................................................................................................... 12
Cleaning Procedure ............................................................................................................................ 12
Jam Clearance..................................................................................................................................... 13
Mounting Guide......................................................................... 14
Recommended Wall Cutout................................................................................................................ 15
Warning
Never remove, unplug, or replace any components inside this machine without first turning off the mains power. Failure to comply may result in damage to your machine and void your warranty.
While every effort has been made to ensure that the information contained in this literature is accurate, Anztec reserves the right to amend the size and specifications of this machine in line with its policy of continuing improvement and development.


QC-5002 Page
4
Installation
Overview
To prepare your
Quick Change for use, you need to:
 Connect the machine to a power source
Reset the system
 Load the coins
The following installation instructions show you how to do this.
Start Up
To start the machine:
1. Unpack and install the equipment supplied.
2. Open the Main Door of the machine.
3. Plug the
QC-5002
power cord into the internal three pin socket. Plug the other end into a mains supply outlet.
4. Switch the unit on using the Mains Switch on the Power Supply Front
Panel.


QC-5002 Page
5
Reset Meters and Events to zero
To reset the meters and events to zero:
1. Start with the machine powered down. Press and hold down buttons 1 and 3 while the machine powers up. Release both buttons.
2. Press button 2.
The machine has now been reset to zero and is ready to accept currency.
Fill Hoppers
This unit is designed to pay out automatically. When the correct funds have been inserted, the
Quick
Change will dispense the appropriate number of coins. Partial credits will be held until further funds are inserted to enable payout.
If the machine becomes empty in the course of operation, simply add coins and turn the machine off and on again. The machine will resume payout where it left off when the hopper was emptied.
To add coins to the hopper:
1. Check that there are no rubber bands, coin bags, or other foreign bodies in with the coins.
2. Check that you are placing the correct denomination of coins into the correct hopper.
3. Pour the coins into the hopper.
SYSTEM RESET?
PUSH B2 TO PROCEED
INSERT CURRENCY NOW
$0.00


QC-5002 Page
6
Daily Management
Overview
Once you have installed the
Quick
Change, you can enter Attendant
Mode to perform the following functions when required:
 Access Event Log
 Access Accountancy Menu
 Clear Short Term Meters
The following daily management instructions show you how to do this.
Enter Attendant Mode
1. Press button 3 to enter Attendant Menu. There are four screens in this menu.
A
2. Press button 1 to move through the menu.
B
C
D
To exit Attendant Menu, use buttons 1 or 2 to move to screen D.
Press button 3 to return to normal operation.
If no buttons are pressed for 30 seconds the machine will return to normal operation automatically.
ATTENDANT MENU
EVENT LOG
ATTENDANT MENU
ACCOUNTANCY
ATTENDANT MENU
CLEAR S/TERM METERS
ATTENDANT MENU
EXIT


QC-5002 Page
7
Access Event Log
The
Quick
Change event log records the last 10 events. It records:
 Notes accepted (by denomination)
 Coins accepted (by denomination)
Notes dispensed
 Coins dispensed (by number)
To access the event log:
1. Press button 3 to enter Attendant Menu.
2. Press button 3.
3. Press buttons 1 or 2 to move through the event log.
To exit this menu press button 3. Move through the menus by pressing buttons 1 or 2 until you reach the exit menu. Press button 3 to return to normal operation.
If no buttons are pressed for 30 seconds the machine will return to normal operation automatically.
ATTENDANT MENU
EVENT LOG
LAST EVENT SHOWN
FIRST


QC-5002 Page
8
Event List
The following is a list of the events recorded by the event log.
Hoppers
Hopper 1 empty
Hopper 2 empty
Coins In
Coin in channel 1
Coin in channel 2
Coin in channel 3
Coin in channel 4
Coin in channel 5
Coin in channel 6
Notes In
Note in channel 1
Note in channel 2
Note in channel 3
Validator cheated
Note jammed
Validator faulty
Coins Out
Coins out hopper 1
Coins out hopper 2
System
Machine powered up
System clear
Short term meter clear


QC-5002 Page
9
Access Accountancy Menu
The
Quick
Change has 16 electronic meters which you can access while in Accountancy Mode. This mode overrides all functions other than Service
Mode.
In Accountancy Mode, you can zero all the short term accountancy meters. To reset the long term meters, refer to Reset Meters and Events to Zero on page 5.
1. Press button 3 to enter Attendant Menu.
2. Press button 1 to move Accountancy Menu.
3. Press button 3 to enter Accountancy Mode.
4. Press button 3 to enter Short Term Meter Mode, or button 1 to enter
Long Term Meter Mode.
5. Press buttons 1 or 2 to view meters.
To exit this menu and return Attendant Menu, press button 3. Move through the menus by pressing buttons 1 or 2 until you reach the exit menu. Press button 3 to return to normal operation.
If no buttons are pressed for 30 seconds the machine will return to normal operation automatically.
ATTENDANT MENU
EVENT LOG
ATTENDANT MENU
ACCOUNTANCY
SELECT ACCOUNT MODE
SHORT TERM
10C COINS IN
0 COINS


QC-5002 Page
10
Accountancy Meter List
Meter No
Number and value of coins in
1 10c
2 20c
3 50c
4
$1.00 5
$2.00
Value of total coins in:
6
Total coins
Number and value of notes in:
7
$5.00 8
$10.00 9
$20.00 10
$50.00 (Not Used)
11
$100.00 (Not Used)
Value of total notes in:
12
Total notes
Total value in:
13
Grand total in
Payout:
14
Hopper 1 paid out
15
Hopper 2 paid out
Total value out:
16
Grand total out


QC-5002 Page
11
Clear Short Term Meters
1
Press button 3 to enter Attendant Menu
2
Press button 1 to move through the menu to:
3
Press button 3 to enter Meter Clearance screen.
4
Press button 3 to clear short term meters. To exit this menu press button 1 or 2.
Move through the menus by pressing buttons 1 or 2 until you reach the exit menu. Press button 3 to return to normal operation. If no buttons are pressed for 30 seconds the machine will return to normal operation automatically.
ATTENDANT MENU
EVENT LOG
ATTENDANT MENU
CLEAR S/TERM METERS
PUSH B3 TO CONFIRM
S/TERM METER CLEAR
SHORT TERM
METERS CLEARED


QC-5002 Page
12
GBA Note Acceptor Maintenance
Equipment Required
A Cotton Swab or lint free cloth.
Cleaning Solution, a mix of water and up to 50% Isopropyl Alcohol is recommended.
Note: do not use more than 50% Isopropyl Alcohol.
Note: Never use cleaning agents as the unit may be severely damaged.
Cleaning Procedure
Anti-Static Precautions should be observed when cleaning validator head.
1. Ensure the supply to the validator is switched OFF.
2. Disconnect external host loom.
3. Depress the two purple buttons on the sides at bottom of the unit and pull backwards to release the validator from the front panel bracket.
4. Move the two purple latches inwards to unlatch and then gently pivot the top section backwards to open.
5. Using the cotton swab or cloth dipped in the cleaning solution – carefully clean all sensors and plastic windows using light force only.
6. Continue with swab etc to clean note path, all rollers and belts.
7. Use an additional swab or cloth to dry area cleaned if required.
8. Re-attach top housing and gently push down on the lid until the latches re-engage.
9. Push the unit back onto the front panel bracket.
10. Reconnect host loom.
11. The supply to the validator can now be switched ON


QC-5002 Page
13
GBA ST2 in open position ready for cleaning
Jam Clearance
1. Ensure the supply to the validator is switched OFF.
2. Disconnect external host loom.
3. Depress the two purple buttons on the sides at bottom of the unit and pull backwards to release the validator from the front panel bracket.
4. Move the two purple latches inwards to unlatch and then gently pivot the top section backwards to open the ST2 and remove the jam.
5. Clear any debris from the note path.
6. Reassemble and reinstall unit.


QC-5002 Page
14
Mounting Guide
To install the unit:
 Remove the angle clamping brackets from the cabinet.
 Push unit through the aperture from the outside until the front panel is hard against the wall.
 Re-bolt the clamping brackets loosely to the cabinet.
 Push the clamping brackets up against the wall and tighten the bolts on the cabinet to lock it into place.
 The forward facing bolts on the clamping brackets can be adjusted for extra tension.
 Plug power cord into power supply, switch on and the unit is installed.
Wall thickness 100mm – 200mm
Front Panel
Rear door
Clamping Bracket
Locking Bolts


QC-5002 Page
15
Recommended Wall Cutout
Recommended Wall Cutout and Mounting Height
450mm
810mm
860mm



Share with your friends:


The database is protected by copyright ©userg.info 2017
send message

    Main page

bosch
camera
chevrolet
epson
fiat
Harley Davidson
Honda
iphone
mitsubishi
nissan
Panasonic
Sony
volvo
xiaomi
Xperia
yamaha