Troubleshooting Troubleshooting Problem Probable cause(s) Remedy Fixture is completely dead. No power to fixture. Check AC mains power and connections. Internal circuit fault. Have faulty fixture serviced by Martin service technician. One or more fixtures resets correctly but responds erratically or not at all to the controller. Fault on data link. Inspect connections and cables. Correct poor connections. Repair or replace damaged cables. Data link not terminated. Insert termination plugin output connector of the last fixture on the link. Incorrect fixture DMX addressing. Check addressing on fixture and controller. Check fixture is set to correct DMX mode. One of the fixtures is defective and is disturbing data transmission on the link. Unplug XLR in and out connectors and connect them directly together to bypass one fixture at a time until normal operation is regained. Have faulty fixture serviced by Martin service technician. XLR pin-out on fixtures does not match (pins 2 and 3 reversed). Install a phase-reversing cable between the fixtures or swap pins 2 and 3 in the fixture that behaves erratically. Light output shuts down unexpectedly. Fixture is too hot. Clean the fixture, especially air vents. Ensure free airflow around fixture. Check that ambient temperature does not exceed max. permitted level. Switch to FULL cooling mode. If problem persists, contact Martin for advice.