13.
Monitor the fill level of the spoils tank by checking the sight glass on the front of the tank.
Figure 5-16. Monitor the fill level of the tank using
the sight glass.
A clogged wand or hose will also stop vacuum pressure. If the pressure stops and the tank is not full, seethe instructions in the Unclogging the Vacuum section below.
14.
When the tank fills with liquid, a ball valve in the top of the tank shuts off the vacuum pressure. (The relief valves in the filter canister will open) Seethe instructions in the next section, Emptying the Tank”.
15.
When vacuuming is completed or when the vacuum pressure stops, turn the Vacuum/Pressure Washer switch to the OFF position.
Figure 5-17. Turn the Vacuum/Pressure Washer
switch OFF to turnoff the vacuum.
NOTE