Part No. MAN, Rev. 1-0809 Cycling Antifreeze out of the System
Propylene glycol (PG) antifreeze comes in two types, motor vehicle and RV/Marine. These antifreezes are intended for completely different end uses. Use only RV/
Marine antifreeze in the
sprayer system. When cycling antifreeze out of the system, do not dump antifreeze on the ground or into storm water drains. Cycle it back into the priming tank, then remove the priming tank and dispose of the antifreeze in an approved manner.
Use freshwater to cycle antifreeze out of the sprayer system when returning the unit to service or prior to starting the unit after it has been stored during freezing weather. If the optional water heater is installed, heated water maybe used.
1.
Fill the water tank with fresh water.
2.
Move the yellow Water Supply Valve lever (in front of the left fender) to the TANKS position.
Figure 4-3. Move the Water Supply Valve to the
TANKS position.
3.
Start the engine and run at low to medium throttle.
4.
Pull a sufficient length of hose from the sprayer hose reel to reach the priming tank remove the tank lid and hold the hose in the tank.